Free delivery on orders over AED 200.
01 / 03
SmartLine elementPlatinum
CSDA 7001 FL
as downdraft extractor for extraction or recirculation operationProduct details
- Intuitive quick selection via number sequences –Smart SelectLoading...
- Elegant design – for flush or raised installation
- Seamlessly integrates with anySmartLine elementLoading...
- Efficient filtration-10-ply stainless-steel grease filterLoading...
- Energy-efficient and quiet - powerfulECO motorLoading...
- View manufacturer details:
- Safety Information
Product data sheet
- Model identifier
- CSDA 7001 FL
- Manufacturer material number
- 11402230
- EAN number
- 4002516304906
- Marketing classLoading...
- Platinum
- Downdraft extractor
- Type of air guide
- Can be retrofitted
- Recirculation conversion kit (order separately)
- DUU 1000-2
- Flat ducting components (order separately)
- DFK- xxxx
- Flush
- Frameless – surface-mounted
- Operation via sensor controls
- SmartSelect
- Digital power level display
- Display colour
- Yellow
- Run-on time 5 min.
- Energy efficiency class (A+++ to D)
- A++
- Annual energy consumption in kWh/year
- 25.3
- Fluid dynamic efficiency class
- A
- Grease filtering efficiency class
- B
- Easy to clean ceramic glass
- Easy-to-clean canopy interior – CleanCover
- Loading...
- Number of dishwasher safe stainless-steel grease filters (10-ply)
- 1
- Air throughput in Level 1 (m³/h) according to EN 61591
- 150
- Air throughput in Level 2 (m³/h) according to EN 61591
- 290
- Air throughput in Level 3 (m³/h) according to EN 61591
- 440
- Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3
- 58
- Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13
- 29
- Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13
- 43
- Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13
- 51
- Sound power in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13
- 55
- Air throughput in Level 1 (m³/h) according to EN 61591
- 100
- Air throughput in Level 2 (m³/h) according to EN 61591
- 235
- Air throughput in Level 3 (m³/h) according to EN 61591
- 380
- Air throughput in Booster level (m³/h) according to EN 61591
- 460
- Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3
- 49
- Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3
- 63
- Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3
- 73
- Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3
- 78
- Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13
- 49
- Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13
- 58
- Sound power in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13
- 63
- Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13
- 34
- Safety switch-off
- FlameGuard
- Dimensions (W x D) in mm
- 222<NBSP/>x<NBSP/>89
- Dimensions in mm (width)
- 120
- Dimensions in mm (height)
- 168
- Dimensions in mm (depth)
- 520
- Casing height incl. connection box in mm
- 168
- Cutout dimensions in mm (width) with surface-mounted installation
- 100 mm
- Cutout dimensions in mm (depth) with surface-mounted installation
- 500 mm
- Inner cut-out dimensions in mm (width) with flush installation
- 100
- Inner cut-out dimensions in mm (depth) with flush installation
- 500
- Outer cut-out dimensions in mm (width) with flush installation
- 124
- Outer cut-out dimensions in mm (depth) with flush installation
- 524
- Weight in kg
- 11
- Total rated load in kW
- 0.170
- Voltage in V
- 230
- Fuse rating in A
- 10
- Number of phases
- 1
- Length of supply lead in m
- 2
- Plinth fan with vent connection
- Extraction connection at rear and side
- Dimensions of the exhaust ducting connector in mm
- 222
- Dimensions of the exhaust ducting connector in mm
- 89
- Ducting system to the plinth fan
- Loading...
- Ducting system to the plinth fan
- Loading...
- EAN
- 4002516304906
What's included
- Ducting system to the plinth fan
- Ducting system to the plinth fan
Easy to use thanks to SmartSelectSmartSelect
Quick and intuitive: power levels and times can be selected separately for each cooking zone.
Safety

FlameGuard
Completely safe: thanks to the FlameGuard, the gas flame cannot be drawn into the countertop extractor.User convenience

SmartSelect
Quick and intuitive: power levels and times can be selected separately for each cooking zone.Matching products and accessories
Downloads
Whether you are looking to replace an appliance or plan a new kitchen – you will find all the relevant installation drawings for your Miele appliance here. Please note that our products should only be installed and maintained by authorised experts. In the event of queries, please ring us for some no-obligation advice!



Descriptions
CSDA 7001 - flush (Installation drawing)
1) front, 2) Fan (in the plinth lying on the floor), 3) Stepped cut-out, 4) 12 mm wooden panel (not supplied as standard), 5) Air duct, 6) E-box POSTSCRIPT

Descriptions
CSDA 7001 - supported installation (Skizze)
1) front, 2) Fan (in the plinth lying on the floor), 3) Air duct, 4) E-Box, POSTSCRIPT

Descriptions
Plinth blower for CSDA 7001 (Installation drawing)
Plinth blower for CSDA 7001 (Installation drawing) POSTSCRIPT
- 1.All product prices incl. VAT at 5%.
We reserve the right to make technical changes; we assume no liability for the accuracy of the information provided.








